2017年8月30日星期三

When the cooling tower is running, observe the details

500mm*1230mm crossflow cooling tower packing fill
    We all know that the cooling tower is installed in the cooling tower inside the cooling tower is a circulating cooling water sprayed in the tower to the filler, so that direct contact with the air, through the evaporation and convection to carry the heat to the atmosphere To the cooling device.
width 380mm bac counter flow cooling tower pvc fill
    Its operation has the following need to pay attention to:
1, reducer should always check the oil level, lubricating oil recommended 22 ~ 28 hyperbolic gear oil or 90 ~ 120 industrial gear oil, the summer with a large viscosity of the oil. The first run after 20 days will be empty oil, new oil.
bac Cooling tower PVC sheet filler for thermoforming
2, fan, motor, reducer before running according to the corresponding product manual inspection, especially the motor wiring, according to the wiring diagram provided by the motor factory wiring, and sometimes the parties that are inconsistent, easy to cause wiring error. Meet the requirements and then start, start the order, from low to high speed.
1230*1000mm Mesan cooling tower film fill
Blade angle according to the provisions of the sample after the installation, such as high-speed running current exceeds the rated value, should immediately stop, speed and contact manufacturers. Adjust the fan blade angle to meet the requirements of the standard is: A, in the fan blades from the top of the fan 150mm at the upper and lower edge of the line to get the point and the next point of the height difference Δh value, each leaf Δh value of the maximum and minimum difference More than 2mm; B, from the windmill 150mm at the edge of the elevation value of the blade, the maximum and minimum value of each leaf elevation value should not be greater than 0.002R (R for the fan radius); C, the motor current is equal to the high-speed operation Value of 0.9 to 0.95.
Pakistan spindle cross flow PVC square cooling tower media fill
For more information, please visit our website: www.coolingtowerfiller.com, or contact us with E-mail, our E-mail address is rask@coolingtowerfiller.com, you can also chat us straightly on whatsapp: 008618330029204, you can also call our boss straightly: 008615930159213

没有评论:

发表评论

closed type cooling tower

new 1000*1300mm spindle cooling tower pvc fill pack Cooling Tower has roots inside the cooling tower industry that span again greater t...