Hebei LongTime Cooling Tower fill Co., Ltd

Hebei LongTime Cooling Tower Co.,Ltd. was founded on the ideas of quality, integrity, worth, and safety.
These rules are the driving force behind our dedication to all of our prospects.
We continuously attempt to provide the utmost in service at costs which can be really fair and affordable.
From the biggest development, improve, repair or upkeep mission, to gross sales of the smallest elements, Hebei LongTime Cooling Tower Co.,Ltd. delivers most value with probably the most competitive charges you will see that and a top quality of workmanship that’s unsurpassed business wide.
pvc fills of cooling tower
Safety is our primary priority. Our comprehensive security training program is designed to cowl all elements of guaranteeing a safe working atmosphere, from monthly gear inspections, to proper use of PPE, to first help, OSHA 30 hour and CPR certification for all of ur superintendents and foreman, Absolute Cooling Tower Inc. is committed to defending the health and safety of each our workers and yours.
width 380mm bac counter flow cooling tower pvc fill
We’ve in depth expertise and our crews are the most competent and certified within the trade. For all phases of cooling tower construction, repair, upkeep, or performance upgrades, our companies truly are the one supply for all of your wants.
Our clients embrace Major Manufacturing and Course of Plants, Refineries, Hospitals, Chemical Firms, Universities, Generation facilities and Business Buildings in Barrie, Toronto, London and different Ontario areas.
We’ve got a fame of excellence, reliability and superior customer service.
We want to exhibit to you that true quality workmanship is second nature to our crews and administration workforce.
We stay up for servicing your wants!
For more information, please visit our website: www.coolingtowerfiller.com, or contact us with E-mail, our E-mail address is ann@longtimefrp.com, you can also chat us straightly on whatsapp: 008618330029204, you can also call our boss straightly: 008615930159213

2017年8月15日星期二

Choose the right cooling tower equipment effect is good

   Cooling tower filler with the development of technology, and now in many industrial areas, the use of cooling towers is very wide, today's cooling equipment planning not only to consider its conduction effect, but also to focus on the convenience of use and repair. It has a combination of factory assembly method layout planning, but also according to customer needs to plan a particularly large-scale industrial. Find compositions. Results composition compositions.aint composition composition polymers. & Lin Lin total cooling equipment came into being, then we buy cooling equipment, how to buy it? We hereby collected some of the cooling tower filler equipment needs: in the construction of simple, with the use of low cost on the basis of the need for service in place.
    We know that the cooling tower filler equipment cooling tower is the primary feature is the use of coil to the system liquid and air flow separated. Here we will be different types of cooling tower performance and characteristics of a detailed analysis to help you understand and select the cooling equipment cooling tower.
    Open cooling tower: its heat transfer and mass transfer process occurs directly between the water droplets or water film and the surrounding air flow. In the cooling tower, the heat is first transferred from the system liquid in the coil to the coil wall by convection and conduction, and heat exchange is carried out by means of heat transfer and mass transfer. Cooling equipment, the loss of transpiration, splash loss and large loss of sewage.
    Find compositions. the coil is located at the top of the system for repair. The cooling filler of the cooling tower is placed below the coil so that the parallel flow of air through the coil will further increase the cooling efficiency of the system. Compared with the cross flow and countercurrent cooling equipment, the heat transfer effect of the system is obviously increased, which reduces the area of ​​the mixed-flow cooling equipment, reduces the equipment cost and energy consumption, and retains the advantages of easy repair.
For more information, please visit our website: www.coolingtowerfiller.com, or contact us with E-mail, our E-mail address is rask@coolingtowerfiller.com, you can also chat us straightly on whatsapp: 008618330029204

2017年8月14日星期一

necessity of repairing and cleaning cooling tower

The hyperbolic cooling tower is one of the important cold end equipment of the steam turbine generator set, and its cooling performance is very important to the economic and safe operation of the power station. From the structure of the hyperbolic cooling tower, it can be seen that the watering device is one of the main factors that affect its cooling performance.
The cooling tower is composed of S wave or oblique wave filler, water collector and nozzle. The ladle is the main component that affects the heat performance of the cooling tower, which is the core of the heat and mass transfer of the water and gas in the cooling tower. Its role is to flood the water distribution system to form a water film or small water droplets to increase the water and air contact area and extend the flow of water in the tower to create a good heat transfer and mass transfer conditions. It is generally said that the cleaning tower mainly refers to the cleaning of leaching filler.
The hyperbolic cooling tower's water circulation system is an open cooling system where dust and other debris are easy to access. In addition, the cooling water in the circulatory system in the continuous use, due to the water temperature, water velocity changes and water evaporation, a variety of inorganic ions and organic matter concentration and equipment structure and materials and other factors combined effect , Will produce more serious than the DC system attached to the deposition of sediment and the proliferation of micro-organisms, and the resulting clogged dirt clogging filler and other issues, seriously affect the cooling effect and damage the steam turbine condenser safe production, and even cause economic Loss [1] Specifically, the open cooling circulating water mainly has the following problems:
(1) scaling. Mainly due to two factors:
On the one hand, after the aeration tower, the water with CO2 from the air in the air, so that the water solubility of Ca (HCO3) 2 into a very small concentration of CaCO3, which precipitation, attached to the filler surface scale; Is due to the evaporation of concentrated water cycle, so that water Ca2 + ions, Mg2 + ions to saturation, precipitation into the scale.
(2) dust. The open cooling system makes it easy for dust debris to enter.
The cooling tower conveys dust-enriched air by dampening the water with air for forced convection, which is equivalent to water, so that it enters the system.
(3) ash. Individual power plants for the conservation, the use of clean water containing ash. When the ash contains water through the filler, due to the cooling tower water gap is small, the ash is easy to plug in the filler and with the dirt together. In severe cases, the combination of dirt and ash will be as hard as stones.
(4) biological slime. As the cooling cycle temperature is generally 30 ~ 40 ℃, and oxygen content, temperature suitable, especially for the growth and reproduction of bacteria, so as to breed a large number of algae in the cooling system to form slime. Viscose accumulation in the filler leaking gap, so that the cooling water flow reduced. Serious, these biological slime will block the filler, so that the cooling water can not be uniform, greatly reduce the hydrophilic area, a serious reduction in the cooling effect of the tower. Remove the sticky sludge under the jamming of the pending filler.
Cooling tower cooling effect is reduced, the power system condenser safety, normal and low-cost operation of a great impact. To ensure the system safe, normal, low-cost operation. It is important to clean the cooling tower filler regularly. Only through safe and effective cleaning can achieve the following objectives:
(1) cleaning the cooling tower filler dirt and slime, to ensure normal, the production needs of the cooling effect, improve power generation efficiency;
(2) to protect the filler, to extend its service life;
(3) to save energy and reduce operating costs;
(4) to save maintenance costs, bring potential benefits.
For more information, please visit our website: www.coolingtowerfiller.com, or contact us with E-mail, our E-mail address is rask@coolingtowerfiller.com, you can also chat us straightly on whatsapp: 008618330029204

Suspension of cooling tower fill maintenance management approach

For the closed cooling tower, the fan, spray pump is the key components of the operation of the entire equipment, for the maintenance of these components, we must strictly abide by the necessary management practices, the following we combined cooling tower, for example, Detailed description of the relevant management practices:
1, the fan: the fan must check the fan motor power cut off. Sometimes due to automatic operation and other reasons, the fan will suddenly start a very dangerous. But also in the shutdown when the power to cut off to restore the power supply when the fan suddenly started very dangerous.
⑴, to confirm whether the leaves are deformed, damaged, or with or without dust, dirt and other attachments. In addition, make sure that the gap between the inner surface of the tower and the blade is uniform on the circumference. In addition to any exception.
⑵, fan with a motor to start a frequent stop will produce a failure. Should pay attention to the operation method, so that the number of starts controlled at 4 times / hour or less.
2, spray pump, circulating pump: check the pump, be sure to cut off the power pump. Sometimes due to automatic operation and other reasons, the pump suddenly start very dangerous.
⑴, pressure, flow, current, vibration, noise and so on when the difference is usually a precursor to the fault, it is very important to deal with. So please do the running diary.
⑵, vibration, please check the installation of the pipe or the basic bolt is loose. Sometimes caused by circulating water vibration, in the piping should be considered to install flexible joints, pressure vibration or absorption device.
⑶, if the pump outlet valve closed for a long time running, will make the internal burn out, should pay full attention.
⑷, frequent start, stop will soon burn the motor. Please follow the following benchmarks to control the number of starts. Motor power start number 7.5kw or less 6 times / hour or less 11kw or less 4 times / hour or less
⑸, long-term stop running or maintenance, the winter when the pump stops when the internal water if the ice, the pump will freeze. The pump must be insulated or the internal water drained.
For more information, please visit our website: www.coolingtowerfiller.com, or contact us with E-mail, our E-mail address is rask@coolingtowerfiller.com, you can also chat us straightly on whatsapp: 008618330029204

Related matters about cooling tower maintenance and repair

1. Check the exhaust fan motor and transmission belt maintenance; (motor, V-shaped belt,)
2. Water cleaning and maintenance; (cleaning water dispenser, washing heat deflector, heat sink scaling or off)
3. Water valve maintenance; (adjust the water float, check the water valve opening degree)
4. Water quality replacement (regular replacement of circulating water,)
5. Metal parts cleaning anti-embroidered treatment.
    About maintenance
    1) V-belt of the blower may be slightly elongated during the initial run. Please adjust the belt according to the adjustment method. If the belt is too tight, it will damage the bearing and cause the accident.
    2) Please regularly clean the upper part of the sink water hole, the next sink filter and so on.
    3) Please release the belt when transporting, blower bearing the Department of fuel, and cover the motor. In the initial operation to determine the belt tightening, locking nuts, and in the blower bearing the Department of refueling, but also to confirm whether the tower has a bird's nest or foreign body, and then boot operation.
    4) exchange circulating water at least twice a year.
    5) After evaporation of the circulating water, it will leave the dissolved matter in the water, so that the water concentration increases, the water is concentrated after the corrosive increase, increase the scale, so that the cooling tower capacity is low, piping and equipment damage.
    In order to prevent this situation, it is recommended to use a part of the method of circulating water to solve:
    ① running in the drain valve only open a little (run off when the switch off the drain valve);
    ② the lower part of the sink cleaning and regular change of water;
    ③ to run the water level rise, often overflow;
    ④ assembly automatic water changing device.
    Precautions during winter transportation
    1) discharge of circulating water and scattered water.
    2) In the case of closed type, please open the drain water of the circulating water, the exhaust port and the water pump. Precautions for winter operation When the winter is running, the motor current will increase, please note. To prevent freezing of the lower sink, use an antifreeze heater. Water pump, piping the use of heaters, and do the bottom of the water tank insulation work.
         For more information, please visit our website: www.coolingtowerfiller.com, or contact us with E-mail, our E-mail address is rask@coolingtowerfiller.com, you can also chat us straightly on whatsapp: 008618330029204

The choice of filler type

The choice of cooling tower filler type to consider the separation process requirements, usually consider the following aspects:
(1) high mass transfer efficiency In general, the regular packing mass transfer efficiency is higher than the bulk filler.
(2) flux should be in the premise of ensuring a higher mass transfer efficiency should be selected with a high pan-gas or gas-phase kinetic energy of the filler.
(3) the cooling tower filler layer pressure drop is low.
(4) filler anti-fouling performance, disassembly, easy maintenance.
Selection of filler specifications The choice of filler type: the choice of filler type to consider the separation process requirements, usually consider the following aspects:
(1) high mass transfer efficiency In general, the regular packing mass transfer efficiency is higher than the bulk cooling tower filler.
(2) flux should be in the premise of ensuring a higher mass transfer efficiency should be selected with a high pan-gas or gas-phase kinetic energy of the filler.
(3) the packing layer pressure drop is low.
(4) filler anti-fouling performance, disassembly, easy maintenance.
For more information, please visit our website: www.coolingtowerfiller.com, or contact us with E-mail, our E-mail address is rask@coolingtowerfiller.com, you can also chat us straightly on whatsapp: 008618330029204

closed type cooling tower

new 1000*1300mm spindle cooling tower pvc fill pack Cooling Tower has roots inside the cooling tower industry that span again greater t...