thermoforming pvc fill tower cooling
When the hyperbolic cooling tower packing is attached to or blocked by the dirt seriously affect the cooling effect, the current are generally replaced by all the new filler. I think that all the replacement for the new filler, neither economic nor necessary.
square cooling tower packing media
To build a small power plant cooling tower as an example to analyze:
Its single tower packing about 1300m3, about 30t. According to 10,000 yuan / t calculation, only a filler on more than 30 million. Plus the cooling tower other materials and wages, all the replacement of a hyperbolic cooling tower packing at least 40 million. Moreover, in general, the bottom of the filler is more serious fouling, the upper filler fouling is not serious. Filling material is polypropylene or polyvinyl chloride, similar to the nature of FRP, unless the man-made damage, will not be bad corrosion, most can be completely cleaned by chemical cleaning and then use.
pp plastic heilex ring for Air Purification
Therefore, the replacement of all new filler is not a rational choice. After practice, the device has been taken with a combination of off-line physical cleaning process cleaning part of the old filler, and then replace a small part of the new filler treatment. The total cost is about 60% less than the total replacement of new fillers. From the cooling effect, this approach is the same as using the replacement of all new fillers. Damaged packing crushed and other treatment, but also allows manufacturers to re-use.
new product 760mm Marley cooling tower Polypropylene fill
Therefore, it is feasible to clean and reuse the cooling tower packing.
The above content is based on the actual work of the students encountered problems encountered for reference, if any questions please communicate in time, correction
For more information, please visit our website: www.coolingtowerfiller.com, or contact us with E-mail, our E-mail address is rask@coolingtowerfiller.com, you can also chat us straightly on whatsapp: 008618330029204, you can also call our boss straightly: 008615930159213
订阅:
博文评论 (Atom)
closed type cooling tower
new 1000*1300mm spindle cooling tower pvc fill pack Cooling Tower has roots inside the cooling tower industry that span again greater t...
-
new type Marley cooling tower pvc filler For the reason that cylinder chamber is open to the discharge manifold, no refrigerant gasoline c...
-
750 x 2000mm Kuken cooling tower pp filling Cooling towers are heat rejection devices. They are integral to many refrigeration programs in...
没有评论:
发表评论