2017年8月7日星期一

Cooling tower filler - no filler spray cooling tower characteristics

Cooling tower filler - no filler spray cooling tower characteristics

Fill-free spray cooling tower is sprayed into the mist through the atomization device, so that the air and water, small particles evenly contact, and the packing tower through the water spray nozzle will be distributed on the filler in the film and cold air contact.

1, WGFB without filler Spray cooling tower with ** low pressure centrifugal atomization device (nozzle pressure: 0.035MPa) as a cooling element [on behalf of the traditional packing tower packing and water distribution device, so that the whole tower almost become an empty tower, structure Greatly simplified.

2, WGFB no filler spray cooling tower in the elimination of fillers and water distribution device, the atomization device installed in the air duct above the water jet direction and axial fan suction the same direction of the cold, while the water has increased and decreased two Process, cooling also has a downstream cooling and countercurrent cooling of the two processes.

3, GFN tower due to the cancellation of the filler, so that the tower load greatly reduced, do not need more support beam plate, civil structure simplification, saving civil construction investment.

Technical Features of No Fill Spray Cooling Tower

1, the amount of cold air and cooling water to gas ratio ratio: the tower to cancel the filler after the fan pressure drop, tower resistance is also reduced. Axial fan air volume increases, in the same amount of water, the effective increase in the ratio of gas to water.

2, the cooling medium and the cooling medium in contact with the specific surface area: the tower uses a ** low-pressure device, can be low-pressure water atomization, jetting a small droplet, increasing the spray area to work and update the heat Spread the surface area, quickly latent heat slipped away.

3, the cooling time: the atomization device above the inlet air channel, water atomization oil downstream and countercurrent two ways, spray work, there will be a small part of the suspended state to stay in the spray section, extending the water stay in the tower time. There is plenty of exchange time for cold air and water. WGFB tower using the spray on the rational distribution of the atomization device installed in the air duct above the water mist particles in the tower with downstream and countercurrent two processes, part of the fog in the tower spray section was suspended above the state, So the water in the tower of the residence time greatly extended, full of cold air and water heat exchange time.

For more information, please visit our website: www.coolingtowerfiller.com, or contact us with E-mail, our E-mail address is rask@coolingtowerfiller.com, you can also chat us straightly on whatsapp: 008618330029204

没有评论:

发表评论

closed type cooling tower

new 1000*1300mm spindle cooling tower pvc fill pack Cooling Tower has roots inside the cooling tower industry that span again greater t...